NT3A Multi-parameter Patient Monitors
Download 1:Product material one
Product Name:NT3A Multi-parameter Patient Monitors
| Product Feature | |
| --------------------------------------------------------- | |
| ◆10.4" High Resolution Color TFT LCD | |
| ◆1-8 Channel Waveform Display | |
| ◆7 Leads ECG Waveform Display; ST Segment Analysis | |
| ◆Defibrillation and ESU Protection | |
| ◆Venous Punch | |
| ◆Suitable for Adult, Pediatric and Neonate | |
| ◆Standard Configuaration: ECG, NIBP, RESP, TEMP, SpO2 | |
| ◆Options: Thermal Recorder, CO2, IBP, Central Monitoring Systems | |
| ---------------------------------------------------------- | |
| Product Specification | |
| ◆ECG | ◆Respiration |
| ECG cable: 5 Leads ECG Cable | Measurement range: 0 ~ 120 bpm |
| Lead selection:Ⅰ,Ⅱ, Ⅲ/ aVR, aVL, aVF/ V | Accuracy: ±1 bpm or ±5 % (take the greater one) |
| Gain (mm/mV): 1/4, 1/2,1, 2, 4, Manual/Automatic | |
| Sweep speed (mm/sec): 6.25, 12.5, 25, 50 | ◆Options |
| Heart rate range: 30~300bpm | EtCO2 |
| Heart rate accuracy:±1bpm or ±1 % | Measurement range: 0~150mmHg |
| ST segment analysis (Diagnostic mode): | Accuracy: ±2 MmHg (0~40)mmHg, ±5% (41~70)mmHg |
| a. ST range: -2.0mV~+2.0mV | ±8% (71~100)mmHg, ±10% (101~150)mmHg |
| b. ST accuracy:±0.02mV | Response time: <3 seconds |
| Monitoring mode: Diagnostic 0.05 ~ 100Hz | |
| Monitoring 0.5 ~ 40 Hz | IBP |
| Operating 1.0 ~ 25 Hz | 2 Channels |
| Range: -40 ~330mmHg | |
| ◆Non-Invasive Blood Pressure | Accuracy: ±4 mm Hg or ±4 % (take the greater one) |
| Measurement type: adult, pediatric, neonatal | |
| Measurement range: | Recorder |
| Adult: Systolic 40 ~ 270mmHg | Thermal array recorder |
| Diastolic 20 ~ 200mmHg | |
| Mean 30 ~ 220mmHg | ◆Environment |
| Pediatric: Systolic 40 ~ 180mmHg | Operation Storage |
| Diastolic 15 ~ 160mmHg | Temperature 5 ~ 40 ℃ -20 ~ 55 ℃ |
| Mean 20 ~ 170mmHg | Humidity ≤ 90% ≤ 95% |
| Neonatal: Systolic 30 ~ 140mmHg | |
| Diastolic 15 ~ 100mmHg | ◆Power Requirements |
| Mean 20 ~ 115mmHg | Input: 100~240 VAC, 50/60Hz |
| Accuracy: Meets ANSI/AAMI Sp10 standards | Consumption: ≤ 80VA |
| Over pressure protection | Battery: +12VDC rechargeable battery |
| ◆Pulse Oximeter | ◆Compliance |
| SpO2 measurement range: 0 ~ 100 % | 1. SpO2: ISO 9919 |
| Pulse rate measurement range: 30 ~ 250 BPM | 2. Safety Standards: EN 60601-1 |
| Accuracy: ± 2 % | 3. Alarm: IEC60601-1-8 |
| 4. EMC: EN 60601-1-2, Group 1 Class A | |
| ◆Temperature | 5. Environment : WEEE (2002/96/EC) |
| 2 Channels | |
| Measurement range: 25 ~ 45 ℃ | |
| Accuracy:±0.2 ℃ | |